17,557 research outputs found

    The Impact of Science on Society

    Get PDF
    Four speeches delivered as part of a public lecture series to assess the impact of science on society are presented. The computerization of society, space exploration and habitation, the mechanisms of technological change, and cultural responses are addressed

    Guided-wave approaches to spectrally selective energy absorption

    Get PDF
    Results of experiments designed to demonstrate spectrally selective absorption in dielectric waveguides on semiconductor substrates are reported. These experiments were conducted with three waveguides formed by sputtering films of PSK2 glass onto silicon-oxide layers grown on silicon substrates. The three waveguide samples were studied at 633 and 532 nm. The samples differed only in the thickness of the silicon-oxide layer, specifically 256 nm, 506 nm, and 740 nm. Agreement between theoretical predictions and measurements of propagation constants (mode angles) of the six or seven modes supported by these samples was excellent. However, the loss measurements were inconclusive because of high scattering losses in the structures fabricated (in excess of 10 dB/cm). Theoretical calculations indicated that the power distribution among all the modes supported by these structures will reach its steady state value after a propagation length of only 1 mm. Accordingly, the measured loss rates were found to be almost independent of which mode was initially excited. The excellent agreement between theory and experiment leads to the conclusion that low loss waveguides confirm the predicted loss rates

    Analytical approximations of the Lindhard equations describing radiation effects

    Get PDF
    Starting from the general Lindhard theory describing the partition of particles energy in materials between ionisation and displacements, analytical approximate solutions have been derived, for media containing one and more atomic species, for particles identical and different to the medium ones. Particular cases, and the limits of these equations at very high energies are discussed.Comment: 10 pages, 5 figures, latex2e, submitted to Nucl. Instr. Meth. in Phys. Res.

    Microarray analysis of spring barley cultivars displaying differing sensitivity to physiological leaf spot (PLS)

    Get PDF
    peer-reviewedPhysiological leaf spot (PLS) is a disorder of spring barley (Hordeum vulgare L.), which has become more pronounced in recent years. The initial symptoms are small chlorotic/brown spots on the upper four leaves, which may develop into necrotic lesions with an irregular shape. As PLS occurs on leaves that are directly exposed to sunlight, it is thought that high light stress could be a trigger for the condition. This study concentrates on two cultivars, Cooper and Crusader, which display differential sensitivity to PLS. Biochemical measurements and enzyme assays revealed substantial difference in levels of ascorbate, type III peroxidases, and superoxide dismutase between the chosen cultivars during the 2003 growing season. A global gene expression study, using these field samples, was performed by microarray analysis. This supported the biochemical findings and highlighted additional sets of genes differentially expressed between the cultivars. Transcripts of particular interest, which appeared, included calcium signalling genes, cold-responsive genes and those involved in the assembly of Photosystem I. We conclude that susceptibility to PLS is related to levels of expression of genes with a role in countering the effects of oxidative stress.Teagasc Walsh Fellowship Programm

    Thermoelectric power factor limit of a 1D nanowire

    Full text link
    In the past decade, there has been significant interest in the potentially advantageous thermoelectric properties of one-dimensional (1D) nanowires, but it has been challenging to find high thermoelectric power factors based on 1D effect in practice. Here we point out that there is an upper limit to the thermoelectric power factor of non-ballistic 1D nanowires, as a consequence of the recently established quantum bound of thermoelectric power output. We experimentally test this limit in quasi-ballistic InAs nanowires by extracting the maximum power factor of the first 1D subband through I-V characterization, finding that the measured maximum power factors conform to the theoretical limit. The established limit predicts that a competitive power factor, on the order of mW/m-K^2, can be achieved by a single 1D electronic channel in state-of-the-art semiconductor nanowires with small cross-section and high crystal quality

    Comparison of numerical methods for the calculation of cold atom collisions

    Full text link
    Three different numerical techniques for solving a coupled channel Schroedinger equation are compared. This benchmark equation, which describes the collision between two ultracold atoms, consists of two channels, each containing the same diagonal Lennard-Jones potential, one of positive and the other of negative energy. The coupling potential is of an exponential form. The methods are i) a recently developed spectral type integral equation method based on Chebyshev expansions, ii) a finite element expansion, and iii) a combination of an improved Numerov finite difference method and a Gordon method. The computing time and the accuracy of the resulting phase shift is found to be comparable for methods i) and ii), achieving an accuracy of ten significant figures with a double precision calculation. Method iii) achieves seven significant figures. The scattering length and effective range are also obtained.Comment: 22 pages, 3 figures, submitted to J. Comput. Phys. documentstyle [thmsa,sw20aip]{article} in .te

    Far-field optical microscope with nanometer-scale resolution based on in-plane surface plasmon imaging

    Full text link
    A new far-field optical microscopy technique capable of reaching nanometer-scale resolution has been developed recently using the in-plane image magnification by surface plasmon polaritons. This microscopy is based on the optical properties of a metal-dielectric interface that may, in principle, provide extremely large values of the effective refractive index n up to 100-1000 as seen by the surface plasmons. Thus, the theoretical diffraction limit on resolution becomes lambda/2n, and falls into the nanometer-scale range. The experimental realization of the microscope has demonstrated the optical resolution better than 50 nm for 502 nm illumination wavelength. However, the theory of such surface plasmon-based far-field microscope presented so far gives an oversimplified picture of its operation. For example, the imaginary part of the metal dielectric constant severely limits the surface-plasmon propagation and the shortest attainable wavelength in most cases, which in turn limits the microscope magnification. Here I describe how this limitation has been overcome in the experiment, and analyze the practical limits on the surface plasmon microscope resolution. In addition, I present more experimental results, which strongly support the conclusion of extremely high spatial resolution of the surface plasmon microscope.Comment: 23 pages, 9 figures, will be published in the topical issue on Nanostructured Optical Metamaterials of the Journal of Optics A: Pure and Applied Optics, Manuscript revised in response to referees comment

    Improvements to 232-thorium, 230-thorium, and 231-protactinium analysis in seawater arising from GEOTRACES intercalibration

    Get PDF
    The GEOTRACES program requires the analysis of large numbers of seawater samples for ^(232)Th, ^(230)Th, and ^(231)Pa. During the GEOTRACES international intercalibration exercise, we encountered unexpected difficulties with recovery and contamination of these isotopes, ^(232)Th in particular. Experiments were carried out to identify the source of these issues, leading to a more streamlined and efficient procedure. The two particular problems that we identified and corrected were (1) frits in columns supplied by Bio-Rad Laboratories caused loss of Th during column chemistry and (2) new batches of AG1-X8 resin supplied by Bio-Rad Laboratories released more than 100 pg of ^(232)Th during elution of sample. To improve yields and blanks, we implemented a series of changes including switching to Eichrom anion exchange resin (100-200 μm mesh) and Environmental Express columns. All Th and Pa samples were analyzed on a Neptune multi-collector inductively-coupled-plasma mass spectrometer (MC-ICP-MS) using peak hopping of ^(230)Th and ^(229)Th on the central SEM, with either ^(232)Th, ^(236)U (or both) used to monitor for beam intensity. We used in-house laboratory standards to check for machine reproducibility, and the GEOTRACES intercalibration standard to check for accuracy. Over a 1-y period, the 2 s.d. reproducibility on the GEOTRACES SW STD 2010-1 was 2.5% for ^(230)Th, 1.8% for ^(232)Th, and 4% for ^(231)Pa. The lessons learned during this intercalibration process will be of value to those analyzing U-Th-Pa and rare earth elements as part of the GEOTRACES program as well as those using U-series elements in other applications that require high yields and low blanks, such as geochronology

    Nutrition Strategies for Triathlon

    Get PDF
    Contemporary sports nutrition guidelines recommend that each athlete develop a personalised, periodised and practical approach to eating that allows him or her to train hard, recover and adapt optimally, stay free of illness and injury and compete at their best at peak races. Competitive triathletes undertake a heavy training programme to prepare for three different sports while undertaking races varying in duration from 20 min to 10 h. The everyday diet should be adequate in energy availability, provide CHO in varying amounts and timing around workouts according to the benefits of training with low or high CHO availability and spread high-quality protein over the day to maximise the adaptive response to each session. Race nutrition requires a targeted and well-practised plan that maintains fuel and hydration goals over the duration of the specific event, according to the opportunities provided by the race and other challenges, such as a hot environment. Supplements and sports foods can make a small contribution to a sports nutrition plan, when medical supplements are used under supervision to prevent/treat nutrient deficiencies (e.g. iron or vitamin D) or when sports foods provide a convenient source of nutrients when it is impractical to eat whole foods. Finally, a few evidence-based performance supplements may contribute to optimal race performance when used according to best practice protocols to suit the triathlete’s goals and individual responsiveness
    • …
    corecore